Ć’EPC-96AC EPC-96ACT EPC-100AC„ |
 |

EPC-96AC |

EPC-100AC |


EPC-96ACT |
Measurement
range |
pH 0 14
:
resolution 0.01pH
ORP 1400mV
:
resolution 1mV |
pH 0 14
:
resolution 0.01pH
ORP 2000mV
:
resolution 1mV |
pH 0 14
: resolution 0.01pH
ORP 1400mV
: resolution 1mV
|
Reproducibility |
pH 0.05 ORP
5mV |
pH 0.05 ORP
5mV |
pH 0.05 ORP
5mV |
Transmission
output scope |
DC 4 20mA
(insulated I/O model)
Max. load resistance 500 
Linearity 0.5% |
DC 4 20mA
(insulated I/O model)
Max. load resistance 500 
Linearity 0.5% |
DC 4 20mA(insulated
I/O model)
Max. load resistance 500 
Linearity
0.5% |
Transmission
output range |
pH : 0 14,0 10,0 8,2 12,
3 11,4 14,4 10,6 14
ORP : 1400mV, 1000mV,
700mV, 350mV,-1000 0mV,
0 1000mV,
-700 0mV,0 700mV
(Selected by changing the panel DIG switches) |
pH : 0 14,0 10,0 8,2 12,
3 11,4 14,4 10,6 14
ORP : 2000mV, 1400mV,
1000mV, 700mV, 350mV,
-1000 0mV,0 1000mV,
-700 0mV,0 700mV
(select by changing the internal panel DIG switches) |
pH : 0 14,0 10,0 8,2 12,
3 11,4 14,4 10,6 14
ORP : 1400mV, 1000mV,
700mV, 350mV,-1000 0mV,
0 1000mV,
-700 0mV,0 700mV
(Selected by changing the panel DIG switches) |
Control
functions |
IC contact
point output
2-CH independent
Capacity : AC 250V,3A max(Resistance load) |
IC contact
point output
2-CH independent
Capacity : AC 250V,3A max(Resistance load) |
IC contact
point output
2-CH independent
Capacity : AC 250V,3A max
(Resistance load) |
Control
operation |
ON/OFF control
Upper limit operation (Hi) or lower limit operation (Lo) (selected by changing
the panel DIP switches)
Upper/lower limit setting range
pH meter 0.00 14.00pH
ORP meter 0 1400mV
Scope of control
pH meter 0.1 4.0pH
( 0.1 2.0pH)
ORP meter 1 999mV
( 1 499mV)
(When the proportional range is 0, only ON/OFF control is valid) |
Upper/lower
limit setting range
pH meter 0.00 14.00pH
ORP meter 0 2000mV
Scope of control
pH meter 0.1 4.0pH
( 0.1 2.0pH)
ORP meter 1 999mV
( 1 499mV) |
Time shared proportional
ON/OFF control
Upper limit operation (Hi) or lower limit operation (Lo) (selected by changing
the panel DIP switches)
Upper/lower limit setting range
pH meter 0.00 14.00pH
ORP meter 0 1400mV
Proportional range
pH meter 0.00 4.00pH
(Begins ON/OFF control when set to 0.00)
ORP meter 0 400mV
(Begins ON/OFF control when set to 0)
Period
5O to 300 secs
Scope of control
pH meter 0.1 4.0pH
( 0.1 2.0pH)
ORP meter 1 999mV
( 1 499mV)
(When the proportional range is 0, only ON/OFF control is valid)
Control output shift function
Shift amount is 0 to 50% of period
(When shift amount = 0%, shift function disappears)
Period automatic variation function
When deviation enters in the specific range (F zone), the period T is automatically
extended in accordance with the deviation. (This does not operate when the shift
function is valid.)
F zone
1 to 50% of pH meter proportional range, 1 to 50% of ORP meter proportional
range (If the deviation is within the above setting, the period automatic variation
function will operate.)
Period max. extension time
0 to 300 secs
|
Calibration
functions |
2-point automatic calibration
or manual calibration (select by changing the positions of the internal panel
DIP switches)
2-point automatic calibration
Automatic standard solution identification, automatic potential stability
determination, standard solution types pH 4, 7, 9 (JIS), standard solution combinations
(pH 4, 7) (pH 7, 9)
Manual calibration:
Standard solution types
Recognition:
Difference of 2 or more in pH level |
2-point automatic calibration
or manual calibration (select by changing the positions of the internal panel
DIP switches)
2-point automatic calibration
Automatic standard solution identification, automatic potential stability
determination, standard solution types pH 4, 7, 9 (JIS), standard solution combinations
(pH 4, 7) (pH 7, 9)
Manual calibration:
Standard solution types
Recognition:
Difference of 2 or more in pH level |
2-point automatic calibration
or manual calibration (select by changing the positions of the internal panel
DIP switches)
2-point automatic calibration
Automatic standard solution identification, automatic potential stability
determination, standard solution types pH 4, 7, 9 (JIS), standard solution combinations
(pH 4, 7) (pH 7, 9)
Manual calibration:
Standard solution types
Recognition:
Difference of 2 or more in pH level |
Additional
functions |
Error messages
a. Calibration error
Asymmetry potential, sensitivity, and reaction speed errors, standard solution
error
b. Electrode diagnosis error
Temperature sensor short-circuit, temperature sensor circuit open
c. Outside measurement range error
Over/under full scale
Corrected pumping
force
Transmission power connected during calibration, continuous, hold (immediately
prior hold, selectable hold) (select by changing the internal panel DIP switches)
Measurement value shift function
pH : 2.00pH
ORP : 200mV |
Error messages
a. Calibration error
Asymmetry potential, sensitivity, and reaction speed errors, standard solution
error
b. Electrode diagnosis error
Temperature sensor short-circuit, temperature sensor circuit open
c. Outside measurement range error
Over/under full scale
Corrected pumping
force
Transmission power connected during calibration, continuous, hold (immediately
prior hold, selectable hold) (select by changing the internal panel DIP switches)
Hold contact input during cleaning
1a no voltage contact input (transmission output hold at contact at contact point
ON)
Measurement value shift function
pH : 2.00pH
ORP : 200mV
Input filter time constant switch function
Time constant: None/time constant: Approx. 7 sec (change using internal panel
DIP switches) |
- |
Temperature
compensation
element |
500 (25 )
or 6.8k (25 )
(select by changing the panel DIP switches) |
500 (25 )
Other 6.8k (25 ),
350 (25 )
1k (0 ),
10k (at25 )
support provided
(select by changing the internal panel DIP switches) |
- |
Temperature
compensation
range |
0 100 (for
pH meter) |
0 100 (for
pH meter) |
- |
Ambient
temperature
and
humidity |
-5 40
85% RH or less |
-5 50
85% RH or less |
- |
Power
supply |
AC90 260V 50/60Hz 10W |
AC100 115V
50/60Hz 7VA or
AC200 240V
50/60Hz 7VA |
AC90 260V 50/60Hz 10W |
Construction |
Panel mount : DIN96
x 96
Indoor installation model
Case : SPCC
Panel : ABS |
Outdoor installation model
: JIS C0920
Protection class : 3 (Rain-proof)
Mounting method : 50 A ball or wall mount
Case :
Polycarbonate (Resin color: grayish white)
Hood : SPCC (Color: comparable to DIC G-262)
Mount : SUS 304 |
Panel mount : DIN96
x 96Indoor installation model
Case : SPCC Panel : ABS |
Outside
dimensions |
96(W) x 96(H)
x 145(D)
Case depth : 135mm |
270(W) x 186(H)
x 229(D)
(Not including mount and protruding portion) |
96(W) x 96(H)
x 145(D)
Case depth : 135mm |
Weight |
Approx. 650
g |
Approx.3kg |
Approx.650g |