SLF Series
These process pumps can even be used
for 90
to 100
high-temperature chemicals and since they are made of PFA, they are especially
optimal for transporting liquid chemicals that require high purity.
|
|
|
SLF-L4
|
SLF-H4
|
SLF-R5
|
|
|
 |
SLF-T4
|
SLF-T5
|
SLF-T8
|
|
Features
Two
types of PVdF (difluoride resin = 0 to 90 )
and PFA (tetra-fluoroethylene 0 to 100 ),
which have excellent corrosion resistance to chemicals at high temperatures, for
the main material that contacts the liquid.
PFA
is substituted for the bearing material, so almost no impurities are dissolved
in, so this is optimal for transporting liquid chemicals that require high purity.
Applications
Corrosive
liquid chemicals, acids, alkalines, photograph developers, photograph filters,
bleaches, inks, alkaline batteries, storage batteries
Seawater,
saltwater, pure water, soy sauce, vinegar, sauce fermentation, juices, plating
solutions, surface treatments, filters
Medical
equipment, scientific instruments, isothermal tanks, pharmaceuticals, chemicals,
cosmetics, electronic component etching equipment, photographic plates, dyeing
equipment, waste liquid treatment equipment, processes, hot water circulation
intakes, freezers, water-cooled show cases, air conditioners, drink vending machines,
ice machines, laboratories, test chambers, test plants
|
Option |
"DRY-MONITOR"
Unloaded Operation Prevention Unit (Special
Accessory)
ELEPON DRY-MONITOR is a device that prevents trouble by immediately stopping the
pump when unloaded pump operation is detected. This unit is controlled by the
motor current, so no special equipment needs to be installed in the pump or piping,
etc.
No need to worry about the wiring from the pump to the operation unit or about
anti-explosion, etc., because these can be installed inside the operation unit.
Unloaded operation, shutoff operation, and cavitation can be prevented by setting
the current setting value from the pump stationary value (specifications point)
to an arbitrary current value when the discharge side is shutoff.
Further, the AC device and number of AC device windings (number of conductor passes)
can be changed and the unit used even if the pump capacity or motor capacity changes.
|
Standard
specifications
Power
supply:AC100V,200V,50/60Hz
Ambient
temperature:50
or less
Output
power contact:1C,AC220V,3A
At
start limit: Max. 30 sec (5 min possible with option)
Power
consumption: Approx. 2VA
Paint
color: Mansell 7.5BG-5/4.5
Weight:
Approx. 300g
|
 |
|
|
<SLF Series>@Frequency
50 Hz |
 |

Opening Diameter
Intake x discharge
(mm) |

Rated Performance
Discharge volume
(liters/min) |

Total
Head
(m) |

Motor
Power
(kw) |

NPSH Re
(m) |

Estimated Weight
(Kg minus the motor) |
SLF-L41 |
40A x 20A
JIS 10K
RF flange |
60 |
7 |
0.4(4P) |
1.8 |
24 |
SLF-H41 |
50 |
20 |
0.75 |
2.2 |
SLF-H43 |
25 |
1.5 |
SLF-H45 |
30 |
SLF-H47 |
35 |
SLF-R51 |
50A x 40A
JIS 10K
RF flange |
100 |
10 |
0.75 |
2.4 |
25 |
SLF-R53 |
200 |
15 |
1.5 |
SLF-R55 |
20 |
2.2 |
26 |
SLF-R57 |
25 |
2.2 |
SLF-T41 |
40A x 25A
JIS 10K
RF flange |
100 |
20 |
0.75 5.5 |
2.2 |
53 |
SLF-T43 |
25 |
SLF-T45 |
30 |
SLF-T47 |
35 |
61 |
SLF-T49 |
40 |
63 |
SLF-T51 |
50A x 40A
JIS 10K
RF flange |
400 |
18 |
3.7 |
2.5 |
70 |
SLF-T53 |
23 |
SLF-T55 |
27 |
5.5 |
72 |
SLF-T81 |
80A x 65A
JIS 10K
RF flange |
700 |
10 |
3.7 |
4.0 |
119 |
SLF-T83 |
20 |
5.5 |
122 |
SLF-T85 |
800 |
25 |
7.5 |
4.5 |
SLF-T87 |
30 |
11.0 |
5.5 |
125 |
SLF-T89 |
1000 |
35 |
15.0 |
|
<SLF Series>@Frequency
60 Hz |
 |

Opening Diameter
Intake x discharge
(mm) |

Rated Performance
Discharge volume
(liters/min) |

Total
Head
(m) |

Motor
Power
(kw) |

NPSH Re
(m) |

Estimated Weight
(Kg minus the motor) |
SLF-L42 |
40A x 20A
JIS 10K
RF flange |
60 |
10 |
0.4(4P) |
2.0 |
24 |
SLF-H42 |
50 |
20 |
0.75 |
2.6 |
SLF-H44 |
25 |
1.5 |
SLF-H46 |
30 |
SLF-H48 |
35 |
SLF-R52 |
50A
x 40A
JIS 10K
RF flange |
100 |
10 |
0.75 |
2.8 |
25 |
SLF-R54 |
200 |
15 |
1.5 |
SLF-R56 |
20 |
2.2 |
26 |
SLF-R58 |
25 |
2.2 |
SLF-T40 |
40A
x 25A
JIS 10K
RF flange |
100 |
20 |
0.75 5.5 |
3.0 |
53 |
SLF-T42 |
25 |
SLF-T44 |
30 |
SLF-T46 |
35 |
61 |
SLF-T48 |
40 |
63 |
SLF-T52 |
50A
x 40A
JIS 10K
RF flange |
400 |
20 |
3.7 |
2.5 |
70 |
SLF-T54 |
25 |
SLF-T56 |
30 |
5.5 |
72 |
SLF-T80 |
80A
x 65A
JIS 10K
RF flange |
700 |
10 |
3.7 |
4.0 |
119 |
SLF-T82 |
20 |
5.5 |
122 |
SLF-T84 |
800 |
25 |
7.5 |
4.5 |
SLF-T86 |
30 |
11.0 |
5.5 |
125 |
SLF-T88 |
1000 |
40 |
15.0 |
|
Metering Pumps Series |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
These are process pumps that
were designed for diverse use, safety, and economy for plant waste
water, water purification, and tap water and sewage system, and water
treatment chemicals metering applications as well as for the metering
and transport for chemical, dye, paper, foodstuff, and pharmaceutical
plants.
 |
 |
 |
CR-1N/2N/3N |
CR-4N/5N/6N |
CRM Series |
 |
 |
 |
CRA/3N |
CR-10N/20N/30N |
CR-4DN |
|
Features
The
completely corrosion resistant liquid contact parts come in a wide variety of
types for use with a wide range of liquids.
Standard
units can handle viscosities up to 300 mPa_s. High-viscosity specification units
can handle up to 2,000 mPa_s. For slurry liquids, for example, up to a 10% concentration
of slacked lime can be handled.
The
compact design features less parts, and maintenance and inspection is easy. Hose
connections and flange connections are also possible.
The
small capacity pump (Models CR-1N to CR-3N) uses a planetary gear two-stage reduction
mechanism, and medium- and large-capacity pumps of 200W or more use a worm gear
reduction mechanism to provide long-term worry-free continuous operation.
The
discharge volume can be manually adjusted regardless of whether the pump is running
or stopped.
Application
Chlorine disinfecting (sodium hypochlorite metering), waste water
treatment equipment and chemical metering, water treatment equipment and chemical
metering, food additives, coloring, preservative metering, boiler water treatment
agent metering, slime control agents for paper production, etc., anti-foaming
agents, dye metering, liquid fertilizer metering in plant growing facilities,
metering and transport for various plant applications, laboratories and test plants,
etc.
|
<Single-head Type> |
Model |
Discharge
Volume
ml/min |
Max.
Discharge Pressure
(MPa) |
Electric Motor |
Pump Aperture Diameter |
Weight kg
(PVC) |
Intake Head |
50Hz |
60Hz |
PVC, acrylic |
SUS |
PVdF |
 CRM-02 |
2 20 |
2.4 24 |
1.0 |
100V single
phase
200V single
phase
200V triple
phase
25W |
4
x 9
Hose
connection
JIS10K 13A
Flange
connection |
- |
- |
6.5 |
-1.0m |
 CRM-04 |
4 40 |
4.8 48 |
1.0 |
- |
- |
6.5 |
 CRM-12 |
12 120 |
14 140 |
1.0 |
6
x 11
Hose
connection
JIS10K 13A
Flange
connection |
- |
- |
7.5 |
 CRM-24 |
24 240 |
28 280 |
0.7 |
- |
- |
7.5 |
 CRM-70 |
64 640 |
76 760 |
0.5 |
100V single
phase
200V single
phase
200V triple
phase
40W |
15
x 22
Hose
connection
JIS10K 15A
Flange |
- |
- |
10.0 |
-1.0m |
 CRM-140 |
110 1,100 |
140 1,400 |
0.5 |
- |
- |
10.0 |
CR-1N |
6 60 |
7 75 |
1.3 |
single phase
100V/0.1kW
triple phase
200V/0.1kW |
6
x 11
Hose
connection |
PT3/8" |
8
x 10
PTFE
Hose |
16.5 |
-1.5m |
CR-1-2N |
14 140 |
17 170 |
1.3 |
16.5 |
CR-2N |
27 270 |
33 330 |
1.0 |
17 |
CR-2-2N |
68 680 |
82 820 |
1.0 |
JIS10K 13A
Flange |
17.5 |
CR-3N |
100 1,000 |
120 1,200 |
0.7 |
JIS10K 15A
Flange
connection |
PT1/2" |
JIS10K 15A
Flange |
18 |
CR-3-2N |
160 1,600 |
190 1,900 |
0.7 |
18 |
CR-4N |
210 2,100 |
250 2,500 |
0.5 |
triple phase
200V/0.2kW |
JIS10K 20A
Flange |
PT3/4" |
JIS10K 20A
Flange |
25.5 |
CR-5N |
260 2,600 |
310 3,100 |
0.5 |
triple phase
200V/0.4kW |
28.5 |
CR-6N |
500 5,000 |
600 6,000 |
0.3 |
JIS10K 25A
Flange |
PT1" |
JIS10K 25A
Flange |
34 |
 CR-10aN |
1,000 10,500 |
1,200 12,500 |
0.5 |
triple phase
200V/0.75kW
Outdoor type |
JIS10K 40A
Flange |
 |
- |
85 |
-1.0m |
 CR-20aN |
2,000 20,500 |
2,400 24,400 |
0.3 |
JIS10K 50A
Flange |
 |
- |
100 |
 CR-30aN |
3,000 30,000 |
3,600 36,000 |
0.3 |
triple phase
200V/1.5kW
Outdoor type |
JIS10K 65A
Flange |
 |
- |
100 |
|
*Select the (b) type for the CR-10aN, 20aN, and
30aN high-viscosity specifications (up to 2,000 mPa_s).
<Double-head Type>
(The following discharge volumes are for both heads.) |
Model |
Discharge
Volume
ml/min |
Max.
Discharge Pressure
(MPa) |
Electric Motor |
Pump Aperture
Diameter |
Weight Kg
(PVC) |
Intake Head |
50Hz |
60Hz |
PVC, acrylic |
SUS |
PVdF |
CR-1DN |
12 120 |
15 150 |
1.3 |
single phase
100V/0.1kW
triple phase
200V/0.1kW |
6
x 11
Hose connection
|
PT3/8" |
8
x 10
PTFE
Hose |
22.5 |
-1.5m |
CR-1D-2N |
28 280 |
34 340 |
1.3 |
22.5 |
CR-2DN |
54 540 |
66 660 |
1.0 |
23.5 |
CR-2D-2N |
136 1,360 |
164 1,640 |
1.0 |
JIS10K 13A
Flange |
24.5 |
CR-3DN |
200 2,000 |
240 2,400 |
0.7 |
JIS10K 15A
Flange |
PT1/2" |
JIS10K 15A
Flange |
25.5 |
CR-4DN |
210 2,100 |
250 2,500 |
0.5 |
triple phase
200V/0.2kW |
JIS10K 20A
Flange |
PT3/4" |
JIS10K 20A
Flange |
30 |
CR-5DN |
420 4,200 |
500 5,000 |
0.5 |
30.5 |
CR-6DN |
520 5,200 |
620 6,200 |
0.5 |
triple phase
200V/0.4kW |
33.5 |
CR-10DN |
1,000 10,000 |
1,200 12,000 |
0.3 |
JIS10K 25A
Flange |
PT1" |
JIS10K 25A
Flange |
38 |
CR-40DN |
4,100 41,000 |
5,000 50,000 |
0.3 |
triple phase
200V/1.5kW
Outdoor type |
JIS10K 50A
Flange |
 |
- |
145 |
-1.0m |
CR-60DN |
5,800 58,000 |
7,000 70,000 |
0.3 |
JIS10K 65A
Flange |
 |
- |
155 |
|
Note:
1. A sealed external vane indoor type is used for the electric motor in the standard
unit. (CR-1N to 10DN) Irregular voltages, increased safety, and pressure-resistant
anti-explosion electric motors are also available for special order.
2. In addition to the above, triple type CR-1TN (discharge volume is Model CR-1N
x 3) to CR-3TN (discharge volume is Model CR-3N x 3) are available.
3. Pumps for highly viscous applications (up to 200 mPa_s and standard units up
to 300 mPa_s) are available, so specify them when ordering.
4. Please contact us regarding slurry liquid applications. (10% concentration
of slaked lime is possible)
5. Usage temperature PVC: 0 to 50 ,
PVdF/SUS: 0 to 80
6. The above connection apertures and specifications are standard, but special
orders are accepted to meet different requirements.
7. The discharge volumes are shown for a discharge pressure of 0.05 MPa. (Pure
water at room temperature)
8. For the SUS specifications for CR-4N, -5N, -6N, -4DN, -5DN, -6DN, and -10DN,
the discharge volumes are slightly less than those shown above (2% to 4%). Contact
ELEPON for details.
9. A standard curve based on the rigorous testing results table is used for the
performance curve.
Models marked with a
are not made of acrylic.
The
means a prompt payment system has been established.(However, only for standard
PVC models)
<Servo Control type CRA Series> |
Model |
Discharge
Volume
ml/min |
Max.
Discharge Pressure
(MPa) |
Servo
Control Motor
Specifications |
E. E.
Positioner |
Weight
Kg
(PVC) |
50Hz |
60Hz |
CRA-1N |
0 60 |
0 75 |
1.3 |
100V single
phase
50/60Hz
6W |
14 Model
CM-102P
Control
speed
(0 to
100%), 13.3/11
sec,
50/60 Hz |
Model
E-660
or
E-661
(with ratio
setting)
Input signal
4 to 20
mA DC |
20 |
CRA-1-2N |
0 140 |
0 170 |
1.3 |
20 |
CRA-2N |
0 270 |
0 330 |
1.0 |
20.5 |
CRA-2-2N |
0 680 |
0 820 |
1.0 |
21.0 |
CRA-3N |
0 1,000 |
0 1,200 |
0.7 |
21.5 |
CRA-3-2N |
0 1,600 |
0 1,900 |
0.7 |
21.5 |
CRA-4N |
0 2,100 |
0 2,500 |
0.5 |
Model
CM-102-1P
22.8/19 sec,
50/60 Hz |
30.5 |
CRA-5N |
0 2,600 |
0 3,100 |
0.5 |
Model
CM-102-2P
27.6/23 sec,
50/60Hz |
33.5 |
CRA-6N |
0 5,000 |
0 6,000 |
0.3 |
39.0 |
CRA-10aN |
0 10,500 |
0 12,500 |
0.5 |
100V single
phase
50/60Hz
60W |
Model
CM-2410P
17/14 sec,
50/60Hz |
95 |
CRA-20aN |
0 20,500 |
0 24,400 |
0.3 |
Model
CM-2420P
23/19 sec,
50/60Hz |
105 |
CRA-30aN |
0 30,000 |
0 36,000 |
0.3 |
Model
CM-2430P
24/20 sec,
50/60Hz |
120 |
|
<Standard Liquid Contact Materials> |
|
PVC |
Acrylic |
SUS |
PVdF |
Pump head |
PVC |
Acrylic |
SUS-304 |
PVdF |
Diaphragm
holding nuts |
PVC |
PVC |
SUS-304 |
PVdF |
Intake/discharge
connectors |
PVC |
PVC |
SUS-304 |
PVdF |
Diaphragm |
PTFE |
PTFE |
PTFE |
PTFE |
Ball valve |
Ceramic |
Ceramic |
SUS-316 |
PTFE |
0-ring |
FKM |
FKM |
PTFE |
PTFE |
|
*Only PVC is available for the Model CRM Series.
For SUS-316, please specify the SVS Standard.
<Standard Accessories (PVC)> |
|
Blade hose |
Strainer |
Reduction gear oil |
Injection opening |
CRM-02
CRM-04
|
4
x 9
x 3m (1 unit) |
1 |
- |
1 |
CRM-12
CRM-24 |
6
x 11
x 4m (1 unit) |
CR-1N
CR-1-2N
CR-2N |
CRM-70,140
CR-2-2N
CR-3N
CR-3-2N
|
- |
1 |
- |
- |
CR-(4DN)
CR-4N(5DN)
CR-5N(6DN) |
- |
1(2) |
0.3L |
- |
CR-6N(10DN) |
- |
1(2) |
0.3L |
- |
CR-10aN
CR-20aN(40DN)
CR-30aN(60DN) |
- |
- |
0.5L(1.0L) |
- |
|
*Only the strainer is provided as a standard accessory for the CRM-02 to 04 and CR-1N to 2N flange types.
TOP
Back pressure regulating valve |
A backpressure regulating valve must be installed on
the discharge side when a reciprocating fixed-volume pump is used under
the following conditions.
1. For differential back-pressure:
In other words, when the intake side pressure is higher than the
discharge side pressure, the pump's check valve does not have a check effect in
the feed direction, so the liquid flows with a natural head regardless of pump
operation.
2. When the differential pressure difference is less than 0.03 MPa
Generally for fixed-volume pumps, when the differential
pressure is low at under 0.03 MPa, the overfeeding phenomenon occurs,
which causes the determinability (reproducibility) to degrade. In this
case, install a back pressure regulating value set to 0.05 MPa or more
to stabilize the discharge flow. |
 |
<Standard Liquid Contact Materials> |
@ |
Material |
Connection Aperture |
Max. Flow Volume liters/min |
Pressure
Setting Range
(Standard Setting Pressure) |
Applicable Pump Types |

BP-04HK
|
PVC |
4
x 9 hose |
0.2 |
0.15 Mpa fixed |
CRM-02,04 |
BP-06HK |
4
x 11 hose |
0.5 |
0.15 Mpa fixed |
CRM-12,24
CR-1N,1-2N,2N |
BP-13FK |
JIS10K13A
Flange |
1.0 |
0.15 Mpa fixed |
CRM-02,04,12,24
CR-1N,1-2N,
CR-2N,2-2N |
BP-13FV
|
0.1 0.3
Mpa
(0.15 Mpa) |
BP-15FK |
JIS10K15A
Flange |
2.0 |
0.15 Mpa fixed |
CRM-70,140
CR-3N,3-2N |
BP-15FV |
0.1 0.3
Mpa
(0.15 Mpa) |
BP-20FV |
JIS10K20A
Flange |
6.0 |
0.1 0.3
Mpa
(0.1 Mpa) |
CR-4DN,5DN,6DN,
4N,5N |
BP-25FV |
JIS10K25A
Flange |
15.0 |
0.1 0.3
Mpa
(0.1 Mpa) |
CR-10DN,6N |
BP-40FV |
JIS10K40A
Flange |
40.0 |
0.1 0.3
Mpa
(0.1 Mpa) |
CR-10aN,20aN,30aN |
|
*SOS and PVdF are also available as the materials.
TOP
Safety valve specifications |
When installing a shutoff valve in the discharge
valve side and when there is a pressure fluctuation on the discharge
end, a safety valve must be installed.
|
 |
<Standard Liquid Contact Materials> |
@ |
Material |
Connection
Aperture |
Max.
Flow Volume liters/min |
Pressure
Setting Range
(Standard Setting Pressure) |
Applicable
Pump Types |

RP-13FV
|
PVC |
JIS10K13A
Flange |
6.0 |
0.2 0.5
Mpa
(0.3 Mpa) |
CR-1N,1-2N,2N2-2N,
3N,3-2N,4DN,5DN
6DN,4N,5N,6N, CRM |
RP-20FV |
JIS10K20A
Flange |
25.0 |
0.2 0.5
Mpa
(0.3 Mpa) |
CR-10DN,10aN
20aN |
RP-25FV
|
JIS10K25A
Flange |
40.0 |
0.2 0.5
Mpa
(0.3 Mpa) |
CR-30aN |
|
*SOS and PVdF are also available as the materials.
TOP
Air chamber specifications |
Pulsation is a detriment of reciprocating pumps. Please install an air chamber when pulsation must be prevented.
|
 |
<Standard Liquid Contact Materials> |
@ |
Material |
Connection
Aperture |
Applicable Models |

APN-X10-13F
|
PVC |
JIS10K13A
Flange |
CR-1N CR-2-2N
CRM-02,04,12,24,70,140 |
APN-X15-15F |
PVC |
JIS10K15A
Flange |
CR-3N,CR-3-2N
CRM-70,140 |
APN-Y30-20F |
PVC |
JIS10K20A
Flange |
CR-4N CR-5N,
CR-4DN 6DN |
APN-Y40-25F
|
PVC |
JIS10K25A
Flange |
CR-6N,CR-10DN |
AP-150-40F |
PVC |
JIS10K40A
Flange |
CR-10aN |
AP-200-50F |
PVC |
JIS10K50A
Flange |
CR-20aN,CR-40DN |
AP-200-65F |
PVC |
JIS10K65A
Flange |
CR-30aN,CR-60DN |
|
*SOS and PVdF are also available as the materials.
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
Centrifugal Pumps
 |
Used for the pumping, stirring, and spraying of chemicals,
such as strong acids and strong alkalis. |
|
Features
This
is a standardized stainless steel self-priming pump based on a unique superior
self-priming force theory (Model CHS only).
Comprehensive
use of high-grade stainless steel.
High-performance,
high-efficiency made possible by specially designed pump casing and impeller.
Heat-resistant
sealed shaft seal makes possible easy maintenance and management.
Special
Teflon is used in the packing.
Semi-permanency
is provided by just replacing the liner and shaft.
Applications
Corrosive
liquid chemicals, acids, alkalis
Waste
liquid treatment equipment
Food
processing, such as soy sauce, vinegar, sauces, fermentation, and juices
Pharmaceuticals,
chemicals, cosmetics, plating solutions
Various
other processes
|
<Model CHS> |
 |

Model |

Opening
diameter
mm
|

Power
kW |

Rated Values |


/min |

m |


/min |

m |


/min |

m |
50
Hz |
CHS |
25 |
0.2 |
40 |
4.5 |
55 |
4 |
80 |
3 |
32 |
0.2 |
50 |
4.2 |
70 |
3.5 |
100 |
2 |
40 |
0.4 |
80 |
8.5 |
110 |
7.5 |
150 |
6 |
50 |
0.75 |
150 |
9 |
200 |
8.5 |
260 |
7.5 |
65 |
1.5 |
200 |
12 |
300 |
10.5 |
420 |
8.5 |
80 |
2.2 |
420 |
11.5 |
600 |
9.5 |
800 |
7.5 |
100 |
3.7 |
650 |
15 |
900 |
13 |
1200 |
10 |
125 |
7.5 |
900 |
17 |
1200 |
15 |
1600 |
12 |
60
Hz |
CHS |
25 |
0.2 |
45 |
6.5 |
70 |
5.5 |
100 |
3.6 |
32 |
0.2 |
60 |
6 |
80 |
5 |
120 |
2.5 |
40 |
0.75 |
100 |
11.5 |
160 |
9 |
200 |
7 |
50 |
1.5 |
160 |
14 |
220 |
12.5 |
300 |
11 |
65 |
2.2 |
240 |
19 |
360 |
17 |
500 |
14 |
80 |
3.7 |
500 |
16 |
700 |
14.5 |
900 |
12 |
100 |
5.5 |
800 |
19 |
1000 |
17 |
1400 |
14 |
125 |
11 |
1100 |
24 |
1600 |
19 |
2000 |
16 |
|
TOP
<Model 2CHS> |
 |

Model |

Opening
diameter
mm |

Power
kW |

Rated Values |


/min |

m |


/min |

m |
50
Hz |
2CHS |
25 |
0.75 |
55 |
18 |
80 |
16 |
40 |
1.5 |
110 |
21 |
150 |
18 |
50 |
2.2 |
200 |
23 |
300 |
20 |
60
Hz |
2CHS |
25 |
1.5 |
70 |
26 |
80 |
23 |
40 |
2.2 |
160 |
28 |
200 |
26 |
50 |
3.7 |
220 |
34 |
300 |
30 |
|
TOP
<Model CH> |
 |

Model |

Opening
diameter
mm |

Power
kW |

Rated Values |


/min |

m |
50
Hz |
CH |
25 |
0.4 |
60 |
6.5 |
40 |
0.4 |
100 |
7 |
50 |
0.75 |
200 |
9 |
65 |
1.5 |
300 |
11.5 |
80 |
2.2 |
600 |
12 |
100 |
3.7 |
900 |
14 |
125 |
5.5 |
1300 |
18 |
150 |
11 |
2200 |
15 |
200 |
30 |
3800 |
26 |
200 |
37 |
3800 |
33 |
60
Hz |
CH |
25 |
0.4 |
70 |
9 |
40 |
0.75 |
160 |
9.5 |
50 |
1.5 |
220 |
14 |
65 |
2.2 |
360 |
16.5 |
80 |
3.7 |
600 |
18 |
100 |
5.5 |
800 |
21 |
125 |
11 |
1500 |
22 |
150 |
15 |
2400 |
22 |
200 |
37 |
4200 |
28 |
200 |
55 |
4200 |
44 |
|
TOP
<Model MCH> |

Model |

Opening
diameter
mm
|

Power
kW |

Rated Values |


/min |

m |


/min |

m |
MCH-20
(Intake and
discharge) |
20 x 20
|
0.4 |
50 |
14 |
20 |
16 |
MCH-30
(Intake and
discharge) |
32 x 25 |
0.75 |
100 |
14 |
60 |
16 |
|